蓝鲸体育直播

MDLT-ONE

Micro Dilution Tunnel

The MDLT-ONE is designed to sample particulate emissions using the partial flow dilution method. A small portion of the total exhaust is diluted with HEPA* filtered air to create a constant flow rate through particulate filters to collect Particulate Matter (PM). Compliant to the latest regulations, the new MDLT-ONE is very compact and offers faster response by the use of high precision venturi flow meters and a piezo actuated valve.

*HEPA: High Efficiency Particulate Air

Small footprint

Heated filter system and flow controllers installed in a single rack. Swivel connection of tunnel section to cabinet allows flexible installation.

Flow weighting (EPA-approved technology)

Allows user to collect PM on a single filter over all three phases of FTP by adjusting sampling flow rate over the filter to weight the filter face velocity over the three phase of the FTP based on weighting targets. This EPA-approved technology increases the measurement accuracy for meeting the upcoming CARB LEV III 1`mg/mile emission limit and reduces filter weighing cycles from three to one, eliminating manual checks and calculations.

Automatic filter changer

Increases testing efficiency, allowing a maximum of 28 tests to be run without manual intervention. This feature can be mounted in the main rack to keep equipment footprint small.

Automatic calibration software enhances accuracy and ease of use

The MDLT-ONE series performs automatic calibration by flowing air in-series through two venturi flow meters and correcting any difference to zero in the software. This can be included in an automated sequence within a test template.

Integrated Operating Platform

蓝鲸体育直播 ONE series systems employ a common use interface, 鈥溊毒ㄌ逵辈 ONE PLATFORM鈥 offering future expandability and ease of integration into test automation systems.

Applications

PM Emission Measurement of All Engines

R&D Support of Engine and After Treatment System

Complies with worldwide emissions regulations

ISO-16183

EU: Euro VI (HDV)

US: 40 CFR Part 1065/1066

Japan: Post new long term

EU: Stage IV / V (NRMM)

 

 

System outline
PM sampling methodPartial flow dilution method
Control modes for dilutionProportional sampling mode (Const. split ratio)/ Fixed dilution ratio mode (Const. dilution ratio)/ Fixed flow rate mode (Manual control)
Control methods for dilution銉籖eal-time control based on analog input of exhaust flow rate
銉籆ontrol based on learned pattern of exhaust rate
Required signal for gas samplingIsolated analog signal (0 to 10 V)
Flow rate of diluted gas25 to 80 L/min*1 (under the condition of 20 掳C and 101.3 kPa)
Accuracy of dilution ratioWithin 卤 5 % (Confirmed by measuring CO鈧)
When dilution ratio=15 rate at 20 掳C and 101.3 kPa: 53 to 80 L/min
PM mass calculation*2PM mass (in g/test or g/kWh) can be calculated and saved, based on integrated values of flow rated and dilution ratio.
Configurations
System configuration銉籑ain unit: Dilution-tunnel unit
銉籓peration unit: PC, monitor, keyboard and mouse (table is not included)
Utilities銉籔urified air: for dilution gas, 400 to 700 kPa, oil free, at least 100 L/min (at 20 掳C and 101.3 kPa)
Power supply voltage and frequency銉籑ain unit: 100/110/120/200/220/230/240 V AC, 50/60 Hz, single phase
銉籓peration unit: 100/110/120/200/220/230/240 V AC, 50/60 Hz, single phase
Power requirementsMain unit: Max. 3.0 kVA / Operation unit: Max. 0.5 kVA
Dimensions銉籑ain unit: 570 (W) 脳 730 (D) 脳 1700 (H) mm
銉籗pace for operation unit: 900 (W) 脳 500 (D) mm (table is not included)
Mass Main unit: Approx. 300 kg (excluding operation unit)
Number of filter lines Max. 6 lines (5 for sample, 1 for bypass)
Type of filter holder銉幌70 mm type: actual PM sampling area 蠁60 mm, with back-up filter
銉幌47 mm type: actual PM sampling area 蠁38.8 mm*1, with back-up filter*1
Operating conditions
Sampling PressureBetween atmospheric pressure and up to 40 kPa    Back pressure of exhaust line: Less than 1 kPa
Options
Filter auto-changer*3Changer for automatic replacement of PM filter (蠁 47 mm)
Valve switchingAdditional air valve before filter (Replacement of sampling filter on bypass mode)
HOST interface*3LAN communication using a 10 Base T port
Conforms to IEEE802.3 (ISO880 2/3)
Conditioner for dilution air / Compressor

 

*1, For the filter face velocity in the regulations (less than 100 cm/s), the flow rate for the 蠁47 mm filter must be 65 standard L/min.
*2, Input the amount of PM collected on filter to calculate PM mass. It is necessary to input engine output (kW) to calculate the PM mass engine output (g/kWh).
*3, Please contact 蓝鲸体育直播, when you order.

Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

Informationsanfrage

Sie haben Fragen oder W眉nsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Verwandte Produkte

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-730位
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PFS-ONE
PFS-ONE

Partikelfilter-Management-System

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication