Preventing accidents caused by gas leakage is a significant challenge in various production facilities and plants, such as steel manufacturing mills, chemical, petrochemical and other types of facilities. This challenge arises due to the aging of facilities and a decrease in experienced personnel capable of providing safety guidance.
It is of utmost importance to proactively prevent accidents for the well-being and safety of workers, safety of the surrounding environment and residents, and the stable operations of the plant.
鈻 One analyzer for monitoring multiple sampling points over a wide area
The switching of multiple sampling points enables the measurement of a wide area with a single analyzer.
鈻 Excellent maintainability
Compared to installing many simple sensors, our solution involves only one analyzer. This allows maintenance in a single location, contributing to a reduction of maintenance cost and increased work efficiency.
The analyzer equipped with automatic calibration function that facilitates daily maintenance.
鈻 Accurate measurement of gas components across wide range, even at low concentrations
Due to 蓝鲸体育直播's original Cross-Modulation NDIR technology (refer to Fig. 2) adopted to the ENDA-5000 analyzer, it is capable of performing stable and accurate measurements and detecting concentration changes even at low parts per million levels.
Figure 1: Gas leakage detection for accident prevention
Figure 2: Detector design of Cross-Modulation NDIR
We propose the appropriate equipment depending on the site environment, measurement components, and other circumstances.
Stack Gas Analyzer ENDA-5000 Series
Analyzers with excellent long-term stability
Multi-Component Gas Analyzer VA-5000 Series
Capable of simultaneous measurement of 3 sampling points by 1 unit
Explosion-proof Gas Analyzer 51 Series
Explosion proof design for application at petrochemical plant etc.
*Per- and Polyfluoroalkyl Substances
Figure 3. Analyzer for gas leakage detection
Gas component | Min. measurement range | Zero drift / Span drift | Repeatability |
Carbon Monoxide锛圕O锛 | 0-200 ppm | 贵厂卤2%/飞别别办 | 贵厂卤0.5% |
Carbon Dioxide锛圕O2锛 | 0-100 ppm | 贵厂卤2%/飞别别办 | 贵厂卤0.5% |
惭别迟丑补苍别锛圕贬4锛 | 0-200 ppm | 贵厂卤2%/飞别别办 | 贵厂卤0.5% |
笔谤辞辫补苍别锛圕3H8锛 | 0-100 ppm | 贵厂卤2%/飞别别办 | 贵厂卤1.0% |
Nitric Oxide锛圢O锛 | 0-200 ppm | 贵厂卤2%/飞别别办 | 贵厂卤0.5% |
Sulfur Dioxide锛圫O2锛 | 0-200 ppm | 贵厂卤2%/飞别别办 | 贵厂卤0.5% |
Per- and Polyfluoroalkyl Substances (PFAS) | 0-10 ppm | 贵厂卤4%/诲补测 | 贵厂卤1.0% |
Please contact us for PFAS and other types of gas not listed in the table above. For propane gas, 51 series of gas analyzer is utilized.