System outline | ||||||
PM sampling method | Partial flow dilution method | |||||
Control modes for dilution | Proportional sampling mode (Const. split ratio)/ Fixed dilution ratio mode (Const. dilution ratio)/ Fixed flow rate mode (Manual control) | |||||
Control methods for dilution | 銉籖eal-time control based on analog input of exhaust flow rate 銉籆ontrol based on learned pattern of exhaust rate | |||||
Required signal for gas sampling | Isolated analog signal (0 to 10 V) | |||||
Flow rate of diluted gas | 25 to 80 L/min*1 (under the condition of 20 掳C and 101.3 kPa) | |||||
Accuracy of dilution ratio | Within 卤 5 % (Confirmed by measuring CO鈧) When dilution ratio=15 rate at 20 掳C and 101.3 kPa: 53 to 80 L/min | |||||
PM mass calculation*2 | PM mass (in g/test or g/kWh) can be calculated and saved, based on integrated values of flow rated and dilution ratio. | |||||
Configurations | ||||||
System configuration | 銉籑ain unit: Dilution-tunnel unit 銉籓peration unit: PC, monitor, keyboard and mouse (table is not included) | |||||
Utilities | 銉籔urified air: for dilution gas, 400 to 700 kPa, oil free, at least 100 L/min (at 20 掳C and 101.3 kPa) | |||||
Power supply voltage and frequency | 銉籑ain unit: 100/110/120/200/220/230/240 V AC, 50/60 Hz, single phase 銉籓peration unit: 100/110/120/200/220/230/240 V AC, 50/60 Hz, single phase | |||||
Power requirements | Main unit: Max. 3.0 kVA / Operation unit: Max. 0.5 kVA | |||||
Dimensions | 銉籑ain unit: 570 (W) 脳 730 (D) 脳 1700 (H) mm 銉籗pace for operation unit: 900 (W) 脳 500 (D) mm (table is not included) | |||||
Mass | Main unit: Approx. 300 kg (excluding operation unit) | |||||
Number of filter lines | Max. 6 lines (5 for sample, 1 for bypass) | |||||
Type of filter holder | 銉幌70 mm type: actual PM sampling area 蠁60 mm, with back-up filter 銉幌47 mm type: actual PM sampling area 蠁38.8 mm*1, with back-up filter*1 | |||||
Operating conditions | ||||||
Sampling Pressure | Between atmospheric pressure and up to 40 kPa Back pressure of exhaust line: Less than 1 kPa | |||||
Options | ||||||
Filter auto-changer*3 | Changer for automatic replacement of PM filter (蠁 47 mm) | |||||
Valve switching | Additional air valve before filter (Replacement of sampling filter on bypass mode) | |||||
HOST interface*3 | LAN communication using a 10 Base T port Conforms to IEEE802.3 (ISO880 2/3) | |||||
Conditioner for dilution air / Compressor |
*1, For the filter face velocity in the regulations (less than 100 cm/s), the flow rate for the 蠁47 mm filter must be 65 standard L/min.
*2, Input the amount of PM collected on filter to calculate PM mass. It is necessary to input engine output (kW) to calculate the PM mass engine output (g/kWh).