À¶¾¨ÌåÓýÖ±²¥

À¶¾¨ÌåÓýÖ±²¥'s advanced brake emission measurement system for precise and regulatory-compliant testing of particulate emissions.

Brake Emission Measurement Analyzers

Advanced Brake Emission Measurement Solutions

Ensure compliance with evolving global regulations using À¶¾¨ÌåÓýÖ±²¥'s industry-leading brake emission measurement analyzers. With extensive expertise in emission certification testing, À¶¾¨ÌåÓýÖ±²¥ has pioneered brake emission certification methods, making us your trusted partner for regulatory compliance.

Importance of Measuring Brake Emissions

As vehicle emissions regulations evolve, non-exhaust emissions such as brake and tire wear have gained attention. Brake emissions significantly contribute to particulate pollution, making precise measurement essential for regulatory compliance and environmental protection. 

Regulatory Development and Measurement Standards

À¶¾¨ÌåÓýÖ±²¥ actively contributes to the , a global working group defining brake emission measurement standards. Our solutions align with the latest UN-GTR GRPE 2023/4 framework, which establishes methodologies for measuring brake emissions under Euro 7 regulations. We also monitor evolving non-exhaust particulate standards from the California Air Resources Board (CARB).

The Euro 7 emission standard () mandates PM10 limits for light-duty vehicles (LDV), with regulations for heavy-duty vehicles (HDV) and particle number (PN) measurements set to take effect by 2030. UN GTR No. 24 defines standardized test methods for measuring:

  • PM10: Fine particles ≤ 10 μm
  • PM2.5: Fine particles ≤ 2.5 μm
  • SPN10: Solid particle number (≥ 10 nm, volatile particles removed)
  • TPN10: Total particle number (≥ 10 nm, including volatile particles)

For further details on Euro 7 brake emission regulations, visit our dedicated page.

Complete Solutions and Analyzers for Brake Dust Measurement

À¶¾¨ÌåÓýÖ±²¥ provides end-to-end solutions for brake emission testing, helping OEMs and brake system suppliers meet current and future regulatory requirements. Our highly reliable brake emission analyzers are designed for both compliance and advanced research, ensuring precise and repeatable measurements through cutting-edge technology and industry-leading expertise in emission testing.

À¶¾¨ÌåÓýÖ±²¥'s Complete Brake Emission Measurement and Testing System Graphic
À¶¾¨ÌåÓýÖ±²¥ GIANT 5200 Brake Dynamometer for measuring brake emissions according to WLTP at TMD Friction, a leading global supplier of high-quality brake friction solutions.

À¶¾¨ÌåÓýÖ±²¥ GIANT 5200 Brake Dynamometer for measuring brake emissions according to WLTP at TMD Friction, a leading global supplier of high-quality brake friction solutions.

The GIANT 5200 brake dynamometer for brake emissions measurements offers a robust, fully automatic and highly accurate measuring environment for brake dust test procedures of passenger car brakes.

Key Specifications:

  • Small footprint (approx. 2m x 1.8m x 5m)
  • Brake enclosure designed for horizontal air ducting system for GTR compliance and in line with OICA recommendation
  • Quick mounting and dismounting of test specimen in working height
  • Test brake adaptations are designed with the customer for a perfect fit
  • Fully automated execution of the WLTP test cycle with STARS Brake providing a UN GTR No. 24 compliant test report

 

 Technical Specifications:

  • Power: 180 kW
  • Speed Range: ± 0–2400 rpm
  • Max. Drag Brake Torque: 2150 N·m
  • Stop Brake Torque Range: ± 0–3000 N·m
  • Electrical Inertia Simulation Range: 5–180 kgâ‹…m2
  • Max. Hydraulic Pressure: 200 bar
  • Mechanical Inertia: 20 kgâ‹…m2

​â¶Ä‹â¶Ä‹â¶Ä‹â¶Ä‹â¶Ä‹â¶Ä‹

The OBS-ONE-PM collects and measures particulate matter emitted from brake pads and discs using a filter weight method. Its Venturi flowmeter ensures accurate sample gas flow rate measurement, making it a robust solution for regulatory testing. 

Key Specifications

  • Filter Holder: 47mm
  • Flow Rate: 16.59 L/min
  • Cyclone Cutoff Point: PM10 & PM2.5 thresholds as per regulations
  • Compact Design: 350(W) × 310(D) × 470(H) mm
  • Power Supply: 100-240V, 0.3 kVA
  • Weight: Approx. 60 kg

 

Item

Specifications (SPN Meter)

Specifications (TPN meter)

Number of Filter Lines

1 line

1 line

Filter Holder

Φ47 mm

Sample flow rate

 (20℃, 101.3 kPa)

16.59 L/min

Cyclone Cutoff Point

(at 16.7 L/min)

1.5 µm:< 20 %

2 µm:< 50 %

3 µm:> 60 %

4 µm:> 90 %

4 µm:< 20 %

8 µm:< 50 %

12.5 μm: > 60%

20 µm:> 90 %

Outer Diameter Dimensions (HxWxD)

470mm (H) x 350mm (W) x 310mm (D)

Power supply (PS unit)

100/200~240 V

Power Consumption

0.3 kVA

Mass

Approx. 60 kg

    The SPCS-ONE-MT-10 provides real-time, high-accuracy measurement of brake wear particles. It features automatic validation functions, ensuring ease of use and superior precision.

    Key Specifications

    • Measurement Principle: Laser Scattering Condensation Particle Counter (CPC)
    • Particle Size Range: 2.5 μm – 10 μm
    • Sample Flow Rate: 10 L/min
    • Dilution Accuracy: ±10% of set value
    • Power Supply: AC 200-240V, single-phase, 2.1 kVA
    • Weight: Approx. 144 kg

     

    Item

    Specifications (SPN Meter)

    Specifications (TPN meter)

    Measuring Principle

    Laser Scattering Condensation Particle Counter (CPC)

    Measurement Components, Particle Count, Concentration Range

    Number of particles of solid particulate matter

    0–50,000 pcs/cm3 (after in-instrument dilution)

    Sample flow rate (20°C, 101.325 kPa)

    10 L/min

    Cyclone Cutoff Point

    As a 50% cut-off point

    Particle size: 2.5 μm~10 μm

    CPC Counting Efficiency

    65±15% @ 10 nm, 90% @ 15 nm

    Diluted Sample Temperature

    Primary diluent (PND1): 191±10 ºC

    Vaporization unit: 350±10 ºC

    ―

    CPC Sample Gas Temperature

    < 35℃

    Dilution Factor Setting Range

    Primary diluent (PND1): 10~200

    Secondary diluent (PND2): 15

    Particle Concentration Reduction Factor

    0.95 < fr(15nm) / fr(100nm) < 2.0

    0.95 < fr(30nm) / fr(100nm) < 1.3

    0.95 < fr(50nm) / fr(100nm) < 1.2

    fr(di): Reduction factor in particle size di

    Volatile Particle Removal Efficiency

    >99.9 %

    (At C40 particles with median diameter >50 nm and mass concentration of >1 mg/m3)

    ―

    Dilution Accuracy

    Within ± 10% of the set value

    VPR 100nm Solid Particle Transmittance

    Pr(100nm) ≥ 0.7

    Pr (100): Transmittance at a particle size of 100 nm

    Outer Diameter Dimensions (HxWxD) 

    637mm (H) x 434mm (W) x 731mm (D)

    Power

    AC 200/220/230/240 V, single phase

    Power Consumption

    2.1 kVA

    Mass

    Approx. 144 kg

    Why Choose À¶¾¨ÌåÓýÖ±²¥?

    •   Industry Expertise: Decades of experience in emission certification testing

    •   Regulatory Leadership: Active role in defining global brake emission standards

    •   Comprehensive Solutions: Full system integration for brake emission analysis

    •   Reliable & Accurate Testing: Advanced methodologies ensuring compliance

    For more information or to discuss your brake emission measurement needs, contact our experts today!